Arctic Spa Tundra Spezifikationen Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
17
17
Topside Control Panel Buttons
The topside control panel has buttons which you press to set the temperature,
initiate the filtrations cycle, turn the light on, and activate or deactivate the pump(s)
and blower. The Topside control panel display responds to let you know you have
pressed a button, and that the selected function has been performed.
Temperature Control (Up & Down Arrows)
These keys are used to set the temperature of the water. As soon as you press one of
these keys, the display will show the current set point and will keep showing it for
5 seconds after releasing the key. Pressing the keys will either increase or decrease the
current set point. The Set Point logo on the display tells you if the display shows the
current set point or the actual temperature of the water.
The water temperature can be adjusted in 1 degree increments from 59 to 104°F (or
from 15 to 40°C). After a power down, the default set point is 102°F (39°C).
Pump 1 Button
Press the Pump 1 key to turn Pump 1 on. A second press will change Pump
1 speed. A third press will turn Pump 1 off. Note: You may not be able to
shut Pump 1 off if in a filter or heating cycle. A built-in timer will shut
Pump 1 off 20 minutes after it has been started.
The Pump 1 ON triangular icon will appear solid on the display when Pump 1 is
running at high speed. It will flash when Pump 1 is running at low speed.
Pump 2 Button (Optional)
Press the Pump 2 key to turn Pump 2 on High speed. A second press will
turn Pump 2 off. If Pump 2 is left on, it will automatically shut off 20
minutes after it has been started.
The Pump 2 ON triangle icon will appear solid on the display when Pump 2 is
running at high speed.
Pump 3 (On/Off Button) (Optional)
Press the Pump 3 key to turn Pump 3 on High speed. A second press will
turn Pump 3 off. If Pump 3 is left on, it will automatically shut off 20
minutes after it has been started.
The Pump 3 ON triangle icon will appear solid on the display when Pump 3 is
running at high speed.
Note: If Pump 3 is not present, then this switch is used only for the On/Off mode.
A long press (5 seconds) on Pump 3 key is used to turn the entire system on or off.
When power is applied to the unit, it is "On" by default.
3
3
Seitenansicht 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 31 32